Donaldson BOFA BOFA AD Oracle Pro OS Fume Extraction System for Laser Cutters
The BOFA AD Oracle Pro OS Fume Extraction System is a high-performance air filtration solution designed for laser cutters. It effectively removes fumes, particulates, and odors generated during cutting and engraving, helping maintain cleaner air, protect equipment, and support a safer workspace.
- Ideal for selective laser sintering, laser melting, engraving, cutting, welding, and coding and marking.
- Intuitive Pro OS software platform with two-way data stream for real-time system insights.
- Color touchscreen displays live filter status, usage data, and system pressure.
- Configurable alerts and filter life monitor help prevent unexpected downtime.
| List Price: | $4,070.00 |
|---|---|
| Price: | $4,070.00 |
| Price: | $... |
| Order Now: | Processed Immediately Free U.S. Shipping |
BOFA AD Oracle Pro OS Fume Extraction System for Laser Cutters
Efficiently Manage Emissions
The BOFA AD Oracle Pro OS Connect is a mid-sized fume extraction system engineered for a wide range of laser applications, including selective laser sintering, laser cutting, engraving, welding, and coding. Powered by BOFA's advanced Pro OS software platform, it delivers two-way data connectivity, real-time system monitoring, and an intuitive color touchscreen interface. Designed to boost productivity and reduce downtime, this system combines smart technology with flexible installation options in a single, powerful unit.
Key Features of the AD Oracle Pro OS Connect:
- Intuitive Pro OS software platform with two-way data connectivity delivers advanced features to boost productivity.
- The large capacity drop-out chamber of the DeepPleat DUO pre-filter is designed to maximize filter life.
- BOFA HEPA filters are rated to filter 99.995% of particles at 0.3 microns.
- Advanced carbon filters help to capture contaminants and odors, reducing the risk of bypass and tunneling.
- Reverse-flow air technology reduces velocity and changes air direction, causing larger particulates to fall into the filter’s drop-out chamber.
- Automatically senses the local voltage and adjusts accordingly.
- VOC (volatile organic compound) sensor continuously monitors exhaust air.
- The remote stop/start signal ensures that your Donaldson BOFA fume extraction system operates only when your machine is running
Pro OS Smart Software Platform
The AD Oracle Pro OS Connect is built around BOFA's Pro OS, an advanced, user-friendly software platform that brings two-way data connectivity to fume extraction. The color touchscreen provides real-time insights into filter life, system pressure, and operational status, empowering operators to make informed decisions and keep production running smoothly.
- Real-time system status is visible at a glance on a responsive color touchscreen.
- Two-way data stream enables remote monitoring and smarter system management.
- Multi-language support with customizable branding for global and OEM use.
Versatile Laser Application
Engineered for the demanding environments of laser fabrication, the AD Oracle Pro OS Connect handles fume and particulate extraction across a broad spectrum of laser processes. Whether you're running a high-volume laser cutting operation or a precision laser coding line, this system is sized and specified to meet the challenge.
- Supports selective laser sintering and selective laser melting (SLS/SLM).
- Effective across laser engraving, cutting, welding, coding, and marking.
- Mid-sized form factor balances extraction capacity with facility footprint.
Flexible Installation & Easy Maintenance
The AD Oracle Pro OS Connect is designed with practical installation and long-term serviceability in mind. A reversible exhaust box allows the system to adapt to your facility layout, while the separate electrical compartment keeps maintenance tasks straightforward and safe.
- Reversible exhaust box supports external ductwork in multiple configurations.
- A separate electrical compartment simplifies access during routine maintenance.
- USB lock screen and alert configurations add an extra layer of operational control.
Effective Fume and Particulate Filtration
The AD Oracle Pro OS is engineered to capture fumes, particulates, and airborne contaminants generated during fabrication processes. Actively filtering the air at the source, it helps protect operators from hazardous exposure and keeps your workspace compliant with safety standards.
- Designed to extract fumes directly at the point of generation.
- Supports external exhaust of filtered air for maximum air quality control.
- Helps maintain a safer, cleaner working environment for operators.
Intuitive Control Panel and Easy Operation
The AD Oracle Pro OS features a clearly designed control panel that makes system monitoring and adjustments straightforward, even for new users.
- User-friendly control panel with clearly labeled functions.
- Comprehensive manual with installation, operation, and safety instructions.
- Available in AD Oracle Pro OS and Connect configurations for flexible deployment.
Technical Specifications
Features
| Dimensions (HxWxD) | 39.2 x 21.5 x 24.6” (995 x 547 x 626 mm) |
| Weight | 157 lbs (71 kg) |
| Airflow / Pressure | 241 cfm / 96 mbar (410 m³/hr / 96 mbar) |
| Noise level (at typical operating speed) | < 70 dBA |
| Cabinet construction | Brushed stainless steel |
Electrial Data
| Voltage (V) | Frequency (Hz) | Current (A) |
| 230 | 50/60 | 12.5 |
For additional information, please view: